2000.8.13
Chemical Engineering: Wilson Large Rammda fitting from experimental data.
Lecture note of Dr. Hiroshi Yamamoto
Please input Liquid mol%, Gas mol%, bubbling
temperature at certain pressure(Total Pressure).
And input Antoine parameter. Then push calc. button.
Example is Acetone-Benzene System.
If you need Antoine parameter, please refer to Antoine Parameter
If you are lucky enough your browser support old JAVA and proper setting of JAVA option, you will see the window like below.
Please input Antoine parameters for molecular 1 and 2, and input liquid phase Mol1 ration, vapor phase Mol1 ratio and boiling point. Then click Calc Wilson large Rammda button. Program calculate Wilson large Rammda parameters.
If you can not see this window, please give up this old JAVA verson. (This Applet is still running with Mac with FireFox browser. 2011.11.15)
If you have Wilson large Rammda and Antoine parameters, you can get Bubbling point (Dew point) chart, X-Y chart, Activities Coefficient chart.